CAMAC Progress Report Week Ending: November 30, 2001 Week: 44 Tom Folkers: 1. Spent week on site testing new hardware and software. 2. Found the computer room to be a very noisy environment. Much work will need to be done to squelch the noise to a reasonable level. Tom Sargent: 1. I got the last bug out of the servo code that was revealed by the test setup and we took it to the telescope. 2. The system did not perform any better than the previous approach. It overshoots about 100 arcsec. Close analysis of the commanded velocity curve shows a very regular 200 arcsec/sec oscillation with a period of about 5Hz. I think this is at least in part because the algorithm expects very low noise in the velocities and we discovered that the noise in the encoders signals is significant. 3. We also looked at the noise in the encoder signals. It is rather large - about 0.5%. When the telescope is stationary, the encoders show about 200 counts of noise out of 32768. If one axis is moved while the other is held stationary, the noise in the stationary one gets worse. Frequency analysis shows prominent 180Hz and 60Hz noise. This is improved by a factor of 2 by switching to use the old encoder signal cables that go to the Krupp rack. Another factor of 2 can be obtained by increasing the voltage amplitude at the source from 4.5 v to about 10 and then dividing it down to 4.5 at the A/D input. We also discovered that the Traquair A/D's do not have 1KHz filters on their inputs as we expected. 4. I suspect the servo algorithm can be made to work by not feeding back the error signal on every position measurement cycle. Driving it at 100Hz apparently stimulates the 5Hz velocity oscillation. Some more damping is needed. Also the algorithm has to be changed to not be so sensitive to noise in the velocity signal. Pete Hubbard: 1. Travel to the SMT for servo testing. With the telescope not moving we collected sin and cos voltages to look at how much noise is present. The highest amplitude frequency component was 180 HZ with encoder ELV1. The P-P average noise is about 200mv. We also tried using the cable that feed's the antenna CAMAC chassis and the noise was 100mv. Out temporary cables were picking up more noise. 2. Set up new collection system in lab for more testing to see how much noise may be coming from the encoders themselves. Dave Ashby: 1. No Report.